Development will consist of an energy storage facility to provide services to the national grid system on the 2.8ha site, Comprising battery containers, combined power conversion system and transformer units, associated electricial infrastructure, fencing , access track, CCTV, ecologically beneficial landscaping, and associated ancillary development.
Development Address:
Causestown, Stackallen, Navan, Co. Meath
Architect Name:
Location Key:
CAUSESTOWN
Electoral Division:
Incorrect Icl Voter Recor
Planner:
Billy Joe Padden
Social Housing Exempt:
Plan Enforcement #:
IPC
Licence Required:
No
Waste Licence Required:
No
Protected Structure:
No
Protected Structure #:
Development Name:
Proposed Development
Comments
Significant Case Flag:
Comments:
Decision
Decision Date:
22/05/2018
Manager Order:
L700/18
Decision Type:
Conditional
Number of Conditions:
17
Grant Date:
13/07/2018
Grant Managers Order #:
Section 47
Apply?:
Part 5
Apply?:
Expiry Date:
12/07/2023
Decision Description:
an energy storage facility to provide services to the national grid system on the 2.8ha site, Comprising battery containers, combined power conversion system and transformer units, associated electricial infrastructure, fencing , access track, CCTV, ecologically benificial landscaping, and associated ancillary development
to amend the design of the approved development (Planning Ref:lb171475) which comprises of consent for an energy storage facility to provide services to the national grid system on the 2.8ha site, Comprising battery containers, combined power conversion system and transformer units, associated electrical infrastructure, fencing, access track, CCTV, ecologically beneficial landscaping, and associated ancillary development.
the development will consist of permission to amend the design of the approved development (planning reference: LB171475) for an energy storage facility to provide services to the national grid system on the 2.8ha site, Comprising battery containers, combined power conversion system and transformer units, associated electrical infrastructure, fencing, access track, CCTV, ecologically beneficial landscaping, and associated ancillary development on lands in Causestown, Stackallen, Navan, Co. Meath., subject to 17 conditions. Amendments proposed are: - Two phases of development, proposed with the combined capacity of no more than 100MW. - Increase the life of the permission from 5 to 10 years to facilities phase 2. - Amend condition 11 of parent consent (Planning Ref: LB171475) to specify that any remedial road works if required as a result of the development shall be focused on the L3411 from Entrance A to N51 junction. - Amend condition 12 of parent consent (Planning Ref: LB171475) To allow for construction works to be carried out between 0700 and 1900 Monday to Friday and 0800 and 1600 on Saturday. - Increase from 24 to 33 smaller battery containers. 31 of which are orientated in a northwest to southeast direction, with the other two in the southeast corner oriented in an east-northeast to west-southwest direction. - Change from 24 large combined Power Conversion System (PCS) and transformer units to 40 much smaller individual PCS and transformer units. These will no longer be housed in containers but are externally mounted. - Addition of four Low Voltage (LV) cabinets. - Revised layout and size of the grid connection and compliance equipment within the storage area: - Change from a 500m3 underground surface water storage tank to a surface water storage pond, with stock proof fence and gate; - Spare parts container moved from the east to the southwest corner of the ESF compound; - Additional small section of temporary access track and cable trench in west corner for grid related works; - Increase in length of the Modular substation within the ESF. - Removal of Grid transformer off site to be relocated within the associated Grid Connection infrastructure (subject to separate planning application). - Addition of 2No. CCTV Cameras (a total of 7No. CCTV Cameras within the site). - Addition of 5 Security Light Columns
No Environment Impact Assesments Associated with this Application