a) subdivision in rooms in front range of college at first and second floor level to create ensuite bathrooms ancillary to existing bedrooms; b) removal of cast iron waste pipes on external facade of front range and introduction of internal soil stacks within building; c) formation of openings in existing internal partitions between proposed ensuite bathrooms and adjoining bedrooms; d) installation of demountable partition in large ground floor lecture room in front range; e) creation of observation window between existing meeting room and adjoining ancillary room on first floor of front range; f) installation of 2 no. toilet cubicles with lobby on ground floor of front range under main (central) staircase; to include new door opening in stair partition and associated works; g) introduction of glazed smoke screens in central corridor of front range at first and second floor level; h) removal of partitions at second floor level in front range and amalgamation of 5 no. smaller rooms int
alterations to the Residential Wing of the college to convert the existing dormitory rooms to en-suite bedrooms with communal living facilities, together with associated building and site services. The building is a Protected Structure - RPS134
fire safety upgrade works, including fire doors, fire detection, emergency lighting and fire stopping & compartmentalisation of the existing building, together with electrical and heating upgrades and associated building and site services. The building is a Protected Structure
(a) the removal of a section of boundary wall and fencing to West of existing college carpark to form pedestrian link to adjacent public carpark (b) erection of new gated entrance at that location (c) new footpaths from new gated entrance and along Avenue leading from Cathedral Street to the College building and (d) new site lighting, (The proposed works are in the curtilage of two Protected Structures (RPS 99 and RPS 134)
St. Patrick's College Cathedral Street Thurles, Co. Tipperary
works to 3 no. teaching spaces to include installation of seating systems and mechanical ventilation systems, enhancement of building services including lighting and associated minor alterations including removal of existing fixed benches and relocation of fire doors, the proposed works are in the curtilage of a protected structure (RPS 134)
works to the former back kitchen area for use as a student lounge to include alterations to existing building opes, conversion of existing window to a door, new internal finishes, installation of new building services including supply and extract affecting the external elevations and installation of mechanical plant in the existing enclosed yard, the proposed works are in the curtilage of a Protected Structure (RPS 134)
No Environment Impact Assesments Associated with this Application