Planning Application: 091086 (Mayo County Council )
File Number:
091086
Application Type:
PERMISSION
Planning Status:
APPLICATION FINALISED
Received Date:
19/10/2009
Decision Due Date:
09/11/2011
Validated Date:
19/10/2009
Invalidated Date:
Further Info Requested:
10/12/2009
Further Info Received:
15/09/2011
Withdrawn Date:
Extend Date:
Decision Type:
Conditional
Decision Date:
13/10/2011
Leave to Appeal:
Appeal Date:
Commenced Date:
Submissions By:
22/11/2009
Applicant Details
Applicant name:
CONSTANT ENERGY LIMITED
Applicant Address:
Phone Number:
Fax Number:
Corresp.
Address:
Applicant Details
Proposed Development
Development Description:
THE DEVELOPMENT WILL CONSIST OF A 200 MEGAWATT NATURAL GAS FIRED PEAKING POWER PLANT COMPRISING OF THE ELECTRICITY GENERATING STATION, AN ABOVE GROUND NATURAL GAS INSTALLATION AND ELECTRICAL SWITCHYARD, ACCESS ROAD AND ASSOCIATED INFRASTRUCTURE. THE ELECTRICITY GENERATING STATION WILL COMPRISE OF TWO GAS TURBINE GENERATORS EACH CONSISTING OF AN AIR INTAKE FILTER SYSTEM, EXHAUST STACK, AIR VENT STACK, INTER-COOLER SYSTEM, TURBINE CONTROL ROOM AND TRANSFORMERS. THE STATION WILL ALSO COMPRISE OF AN ADMINISTRATION BUILDING, A WATER TREATMENT PLANT, A FIRE FIGHTING PUMPHOUSE, A FIRE/RAW WATER STORAGE TANK, CHEMICAL STORAGE TANKS, DEMINERALISED WATER STORAGE TANK, A BACKUP DIESEL FUEL STORAGE TANK, A FUEL SUPPLY PUMPHOUSE, AIR COOLERS, AIR COOLER CONTROL MODULE, AN EFFLUENT TREATMENT PLANT AS WELL AS ALL ASSOCIATED INTERNAL AND EXTERNAL EQUIPMENT ABOVE AND BELOW GROUND INFRASTRUCTURE, ROADS AND CAR PARKS. THE AGI WILL COMPRISE OF ABOVE GROUND GAS PIPES AND EQUIPMENT, HEATING AND PRESSURE REGULATING BUILDINGS AND ALL ASSOCIATED ROADS AND ABOVE AND BELOW GROUND INFRASTRUCTURE. THE 110KV ELECTRICAL SWITCHYARD WILL COMPRISE OF ABOVE GROUND ELECTRICAL EQUIPMENT BUSBAR, A CONTROL BUILDING AND ALL ASSOCIATED ROADS AND ABOVE AND BELOW GROUND INFRASTRUCTURE. PERMISSION IS ALSO SOUGHT FOR ALL ANCILLARY SITE DEVELOPMENTS INCLUDING LANDSCAPE, BOUNDARY, FIREFIGHTING, AND DRAINAGE WORKS.
Development Address:
CROAGHAUN WEST, BELLACORICK, CO. MAYO
Architect Name:
Location Key:
CROAGHAUN
Electoral Division:
Planner:
None
Social Housing Exempt:
Plan Enforcement #:
IPC
Licence Required:
No
Waste Licence Required:
No
Protected Structure:
No
Protected Structure #:
Development Name:
Proposed Development
Comments
Significant Case Flag:
C
Comments:
extension of duration granted on 9/12/2016: expiry date is now 15/11/2021
Decision
Decision Date:
13/10/2011
Manager Order:
P888/2011
Decision Type:
Conditional
Number of Conditions:
23
Grant Date:
16/11/2011
Grant Managers Order #:
Section 47
Apply?:
Part 5
Apply?:
Expiry Date:
15/11/2016
Decision Description:
THE DEVELOPMENT WILL CONSIST OF A 200 MEGAWATT NATURAL GAS FIRED PEAKING POWER PLANT COMPRISING OF THE ELECTRICITY GENERATING STATION, AN ABOVE GROUND NATURAL GAS INSTALLATION AND ELECTRICAL SWITCHYARD, ACCESS ROAD AND ASSOCIATED INFRASTRUCTURE. THE ELECTRICITY GENERATING STATION WILL COMPRISE OF TWO GAS TURBINE GENERATORS EACH CONSISTING OF AN AIR INTAKE FILTER SYSTEM, EXHAUST STACK, AIR VENT STACK, INTER-COOLER SYSTEM, TURBINE CONTROL ROOM AND TRANSFORMERS. THE STATION WILL ALSO COMPRISE OF AN ADMINISTRATION BUILDING, A WATER TREATMENT PLANT, A FIRE FIGHTING PUMPHOUSE, A FIRE/RAW WATER STORAGE TANK, CHEMICAL STORAGE TANKS, DEMINERALISED WATER STORAGE TANK, A BACKUP DIESEL FUEL STORAGE TANK, A FUEL SUPPLY PUMPHOUSE, AIR COOLERS, AIR COOLER CONTROL MODULE, AN EFFLUENT TREATMENT PLANT AS WELL AS ALL ASSOCIATED INTERNAL AND EXTERNAL EQUIPMENT ABOVE AND BELOW GROUND INFRASTRUCTURE, ROADS AND CAR PARKS. THE AGI WILL COMPRISE OF ABOVE GROUND GAS PIPES AND EQUIPMENT, HEATING AND PRESSURE REGULATING BUILDINGS AND ALL ASSOCIATED ROADS AND ABOVE AND BELOW GROUND INFRASTRUCTURE. THE 110KV ELECTRICAL SWITCHYARD WILL COMPRISE OF ABOVE GROUND ELECTRICAL EQUIPMENT BUSBAR, A CONTROL BUILDING AND ALL ASSOCIATED ROADS AND ABOVE AND BELOW GROUND INFRASTRUCTURE. PERMISSION IS ALSO SOUGHT FOR ALL ANCILLARY SITE DEVELOPMENTS INCLUDING LANDSCAPE, BOUNDARY, FIREFIGHTING, AND DRAINAGE WORKS.
EXTENSION OF DURATION OF P09/1086 - THE DEVELOPMENT WILL CONSIST OF A 200 MEGAWATT NATURAL GAS FIRED PEAKING POWER PLANT COMPRISING OF THE ELECTRICITY GENERATING STATION, AN ABOVE GROUND NATURAL GAS INSTALLATION AND ELECTRICAL SWITCHYARD, ACCESS ROAD AND ASSOCIATED INFRASTRUCTURE. THE ELECTRICITY GENERATING STATION WILL COMPRISE OF TWO GAS TURBINE GENERATORS EACH CONSISTING OF AN AIR INTAKE FILTER SYSTEM, EXHAUST STACK, AIR VENT STACK, INTER-COOLER SYSTEM, TURBINE CONTROL ROOM AND TRANSFORMERS. THE STATION WILL ALSO COMPRISE OF AN ADMINISTRATION BUILDING, A WATER TREATMENT PLANT, A FIRE FIGHTING PUMPHOUSE, A FIRE/RAW WATER STORAGE TANK, CHEMICAL STORAGE TANKS, DEMINERALISED WATER STORAGE TANK, A BACKUP DIESEL FUEL STORAGE TANK, A FUEL SUPPLY PUMPHOUSE, AIR COOLERS, AIR COOLER CONTROL MODULE, AN EFFLUENT TREATMENT PLANT AS WELL AS ALL ASSOCIATED INTERNAL AND EXTERNAL EQUIPMENT ABOVE AND BELOW GROUND INFRASTRUCTURE, ROADS AND CAR PARKS. THE AGI WILL COMPRISE OF ABOVE GROUND GAS PIPES AND EQUIPMENT, HEATING AND PRESSURE REGULATING BUILDINGS AND ALL ASSOCIATED ROADS AND ABOVE AND BELOW GROUND INFRASTRUCTURE. THE 110KV ELECTRICAL SWITCHYARD WILL COMPRISE OF ABOVE GROUND ELECTRICAL EQUIPMENT BUSBAR, A CONTROL BUILDING AND ALL ASSOCIATED ROADS AND ABOVE AND BELOW GROUND INFRASTRUCTURE. PERMISSION IS ALSO SOUGHT FOR ALL ANCILLARY SITE DEVELOPMENTS INCLUDING LANDSCAPE, BOUNDARY, FIREFIGHTING, AND DRAINAGE WORKS.
No Environment Impact Assesments Associated with this Application